In short
HVAC heating repairs cover the air-side equipment that delivers heat in commercial buildings, including air handling unit heating coils, fan coil units, warm-air heaters and associated valves, actuators, fans and controls. Common faults include cold air from vents, frost protection trips, stuck heating valves and fans that do not run. Refrigerant work is only carried out by F gas certified engineers.
What the work may involve
- Air handling unit heating coil and valve repairs
- Fan coil unit heating faults
- Warm-air heater repairs
- Frost protection and low-temperature trips
- Fan, motor and belt faults
- Controls and actuator repairs
Warning signs to report
- Cold air from supply vents in heating mode
- Fan coil units running but not warming the room
- AHU frost protection alarms or trips
- Warm-air heaters not lighting or cutting out
- Noisy fans, belts or bearings
When heat is delivered through air
Air handling units heat incoming air with a heating coil supplied by the boiler plant. Fan coil units heat individual spaces using a small coil and fan. Warm-air heaters in warehouses and workshops may be gas-fired. In each case, cold air means either heat is not reaching the unit or the unit is not using it.
Typical HVAC heating faults
| Symptom | Areas engineers check |
|---|---|
| AHU supplying cold air | Heating valve, actuator, coil supply, controls |
| Frost protection trip | Coil temperature, valve operation, plant supply |
| Fan coil not heating | Unit valve, controller, air lock, setpoint |
| Warm-air heater cutting out | Ignition, flame detection, flue, overheat |
| Fan noise | Bearings, belts, mountings |
Working with the controls
Most HVAC heating is controlled by a BMS. A heating valve that is commanded open but does not move, or a sensor reading the wrong temperature, can look exactly like a mechanical failure. Engineers compare what the controls request with what the equipment does. See heating controls and BMS repairs.
Gas-fired warm-air heaters must be worked on by Gas Safe registered engineers. Refrigerant circuits must be worked on by F gas certified engineers.
Need hvac heating repairs help?
Send the equipment details, symptoms, fault codes and site address through Flair Facilities Ltd, or call to talk it through.
HVAC Heating Repairs FAQs
Why is the air handling unit blowing cold air?
Common causes include a heating valve or actuator that is not opening, no hot water reaching the coil, controls calling for cooling, or a frost protection trip. Engineers check the coil, valve, controls and the heating supply together.
Why do some fan coil units heat and others not?
Individual valves, actuators, controllers, air locks or settings can fail on a unit-by-unit basis. Several failures in one area may point to a circulation or zone problem.
Do you repair heat pumps and air conditioning?
Work on refrigerant circuits must only be carried out by F gas certified engineers. Share details of the equipment when you enquire so the right engineer can be arranged.
What is a frost protection trip?
AHUs have protection to stop coils freezing in cold weather. A trip shuts the unit down, often because the heating coil was not receiving enough heat. The underlying cause needs investigating before restarting.
Useful UK references
- Ventilation in the workplace Health and Safety Executive
- F gas in refrigeration and air conditioning GOV.UK
Last reviewed 24 November 2026. General guidance only; it does not replace a qualified site-specific assessment.