Why Does Commercial Heating Pressure Keep Dropping?

By Commercial Heating Repairs London editorial team · Updated

Quick answer

A sealed commercial heating system that slowly loses pressure usually has a leak, an expansion vessel that has lost its charge, or a relief valve discharging when the system heats up. The pressurisation unit may hide the problem by topping up until it alarms or fails. Recording pressure with the heating cold and hot, and how often the unit runs, helps an engineer find the cause.

How a sealed system holds pressure

Commercial heating systems are usually sealed. A pressurisation unit adds water when pressure falls. An expansion vessel absorbs the extra volume as water heats and expands. A relief valve opens if pressure gets too high. These three work together, so a fault in one affects the others.

The usual causes of pressure loss

Cause Typical clue
Small leak in pipework or emitters Damp patches, staining, drips
Leak inside plant Water around boilers, pumps or valves
Expansion vessel lost its charge Pressure swings widely between cold and hot
Relief valve discharging Water at the relief valve outlet when hot
Air being vented Automatic air vents spitting water

What to record

  • Pressure with the heating cold and at full temperature
  • How often the pressurisation unit runs or alarms
  • Any water at relief valve outlets, drains or around plant
  • Whether boilers have locked out on low pressure

Do not adjust pressurisation settings or isolate vessels unless you are competent and authorised.

Getting it fixed

Pressure faults are covered under pump and pressurisation repairs. If several plant alarms are involved, see plant room repairs.

Questions

Is it OK to keep topping up the pressure?

Repeated top-ups add fresh, oxygenated water that can increase corrosion, and they hide the underlying fault. Find the cause instead.

How is this different from a sudden pressure loss?

A sudden drop usually means a significant leak or failed component and needs urgent attention, especially if boilers lock out. A slow drop over days or weeks suggests a smaller leak or a vessel problem.

General guidance only. It does not replace a qualified site-specific assessment. For gas escapes or carbon monoxide, call the National Gas Emergency Service on 0800 111 999.